• 13.30 kW
  • 16.00 kW
  • Area : 100 M2
7790.00lv.
Price with VAT
Description
  • Highly efficient in heating and cooling mode (A-rating energy efficiency)
  • New 3-dimensional fan for optimised very extensive and consistent air distribution
  • Easy installation and maintenance
  • Remote control with temperature sensor and weekly timer
  • Condensate water pump to a difference in height of 85 cm

 

Model
AUHG 54 LRLA Indoor Unit
AOHG 54 LETL Outdoor Unit
Description Functions
  • Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating
    Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating
  • The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.
    The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.
  • The setting temperature automatically returns to the previously set temperature.
    The setting temperature automatically returns to the previously set temperature.
  • The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.
    The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.
  • The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.
    The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.
  • The up/down flaps automatically swing up and down.
    The up/down flaps automatically swing up and down.
  • The micro-computer automatically adjusts the airflow effectively to follow the changes of room temperature.
    The micro-computer automatically adjusts the airflow effectively to follow the changes of room temperature.
  • In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once power supply is restored.
    In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once power supply is restored.
  • Outside air can be introduced by attaching Locally purchased duct to fresh air knockout and optional part.
    Outside air can be introduced by attaching Locally purchased duct to fresh air knockout and optional part.
  • Fresh air can be taken in by a fan which can be connected using external control unit.
    Fresh air can be taken in by a fan which can be connected using external control unit.
  • Systems are capable of attaching Locally purchased branch ducts distributing the airflow.
    Systems are capable of attaching Locally purchased branch ducts distributing the airflow.
  • Automatically stops operation when a fixed time has elapsed from the start of operation
    Automatically stops operation when a fixed time has elapsed from the start of operation
  • The micro-computer gradually changes the room temperature automatically to afford a comfortable night's sleep
    The micro-computer gradually changes the room temperature automatically to afford a comfortable night's sleep
  • This digital timer allows selection of one of four options: ON, OFF, ON » OFF or OFF « ON.
    This digital timer allows selection of one of four options: ON, OFF, ON » OFF or OFF « ON.
  • Weekly + Setback timer can set temperature for two times spans and for each day of the week.
    Weekly + Setback timer can set temperature for two times spans and for each day of the week.
  • Indicates the filter cleaning period by lamp.
    Indicates the filter cleaning period by lamp.
  • External ON/OFF input
    External ON/OFF input
  • Blue fin
    Blue fin
  • All DC models
    All DC models
  • i-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform.
    i-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform.
  • V-PAM inverter control reduces the effects of magnetic flux and increases the maximum speed and efficiency of the compressor by vector control technology
    V-PAM inverter control reduces the effects of magnetic flux and increases the maximum speed and efficiency of the compressor by vector control technology
Operation modeCooling Heating 
Capacity kW 13.30 16.00
Input Power kW 4,42 4,69
Operation Range °C DB -15~46 -15~24
System data  
Running Current A 19,3 20,5
Power Source V/O/Hz 230/1/50
Moisture Removal I/h 5,0
Piping Connections (Small / Large) mm 9,52/15,88
Max Pipe Length m 50
Max Height Difference m 30
Refrigerant R410A
Grille UTG-UGYA-W
unit indoorOutdoor
Airflow Rate (High) m?/h 2.000 6.750
Net Dimension H x W x D mm 288x840x840 1290×900×330
Weight kg (lbs) 26 (57) 86 (190)
Noise (H/Q) dB(A) 47/43/41/37 55
Drain Pipe Diameter mm 25,0 32,0
Net Dimension H x W x D / Grille mm 50x950x950
Related Posts
Price with VAT:
4350.00
  • New circular flow series for big rooms
  • Unique circular flow design
  • Confortable environment – uniform temperature distribution through wide airflow
  • Fresh air intake
  • Timers for precise operational control
  • Individual louvre control via touch-screen controller
  • Human sensor – efficient energy-saving control
  • Low ambient operation
Price with VAT:
0.00
Price with VAT:
4680.00