• A++6.40
  • 4.30 kW
  • 5.00 kW
  • Area : 30 M2
3450.00lv.
Price with VAT
Description
  • Powerful DC inverter cassette in Euro grids
  • New 2-stage turbo fan for improved air distribution
  • Low-noise operation
  • Easy maintenance and washable long-term filter
  • Available with infrared operation as standard
  • With cable remote control and weekly timer as an optional extra
  • Connection option on side for fresh air supply
Model
AUHG 14 LVLB Indoor Unit
AOHG 14 LALL Outdoor Unit
Description Functions
  • Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating
    Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating
  • The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.
    The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.
  • The setting temperature automatically returns to the previously set temperature.
    The setting temperature automatically returns to the previously set temperature.
  • The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.
    The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.
  • The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.
    The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.
  • The up/down flaps automatically swing up and down.
    The up/down flaps automatically swing up and down.
  • The micro-computer automatically adjusts the airflow effectively to follow the changes of room temperature.
    The micro-computer automatically adjusts the airflow effectively to follow the changes of room temperature.
  • In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once power supply is restored.
    In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once power supply is restored.
  • Outside air can be introduced by attaching Locally purchased duct to fresh air knockout and optional part.
    Outside air can be introduced by attaching Locally purchased duct to fresh air knockout and optional part.
  • Fresh air can be taken in by a fan which can be connected using external control unit.
    Fresh air can be taken in by a fan which can be connected using external control unit.
  • Automatically stops operation when a fixed time has elapsed from the start of operation
    Automatically stops operation when a fixed time has elapsed from the start of operation
  • The micro-computer gradually changes the room temperature automatically to afford a comfortable night's sleep
    The micro-computer gradually changes the room temperature automatically to afford a comfortable night's sleep
  • This digital timer allows selection of one of four options: ON, OFF, ON » OFF or OFF « ON.
    This digital timer allows selection of one of four options: ON, OFF, ON » OFF or OFF « ON.
  • Weekly + Setback timer can set temperature for two times spans and for each day of the week.
    Weekly + Setback timer can set temperature for two times spans and for each day of the week.
  • External error output
    External error output
  • External ON/OFF input
    External ON/OFF input
  • All DC models
    All DC models
  • i-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform.
    i-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform.
  • V-PAM inverter control reduces the effects of magnetic flux and increases the maximum speed and efficiency of the compressor by vector control technology
    V-PAM inverter control reduces the effects of magnetic flux and increases the maximum speed and efficiency of the compressor by vector control technology
Operation modeCooling Heating 
Capacity kW 4.30 5.00
Input Power kW 1,33 1,34
SEER - Energy Class - Cooling W/W 6,40 A++ -
SCOP - Energy class - Heating W/W 4,40 A+
Annual Energy Consumption kWh/a 235 1432
Operation Range °C DB -10~46 -15~24
System data  
Running Current A 6,1 6,1
Power Source V/O/Hz 230/1/50
Moisture Removal I/h 1,5
Piping Connections (Small / Large) mm 6,35/12,70
Max Pipe Length m 25
Max Height Difference m 15
Refrigerant R410A
Grille UTG-UFYB-W
unit indoorOutdoor
Airflow Rate (High) m?/h 680 1.910
Net Dimension H x W x D mm 245×570×570 578×790×300
Weight kg (lbs) 15 (33) 40 (88)
Noise (H/Q) dB(A) 38/34/30/27 49
Drain Pipe Diameter mm 25 32
Net Dimension H x W x D / Grille mm 49x700x700