Description
- Highly efficient (COP to 3.71)
- Self-diagnostic system
- Infrared remote control
- Automatic operation
- Dehydrating function
- 24-hour timer
- Infrared remote control
- Available with cable remote control as an option
Model
ABHG 45 LRTA | Indoor Unit |
AOHG 45 LATT | Outdoor Unit |
Description Functions
-
Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating
-
The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.
-
The setting temperature automatically returns to the previously set temperature.
-
The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.
-
The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.
-
Complex swing action of flaps enables automatically to swing both horizontal and vertical directions.
-
The micro-computer automatically adjusts the airflow effectively to follow the changes of room temperature.
-
In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once power supply is restored.
-
Outside air can be introduced by attaching Locally purchased duct to fresh air knockout and optional part.
-
Fresh air can be taken in by a fan which can be connected using external control unit.
-
Automatically stops operation when a fixed time has elapsed from the start of operation
-
The micro-computer gradually changes the room temperature automatically to afford a comfortable night's sleep
-
This digital timer allows selection of one of four options: ON, OFF, ON » OFF or OFF « ON.
-
Weekly + Setback timer can set temperature for two times spans and for each day of the week.
-
External error output
-
External ON/OFF input
-
All DC models
-
i-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform.
-
V-PAM inverter control reduces the effects of magnetic flux and increases the maximum speed and efficiency of the compressor by vector control technology
Operation mode | Cooling | Heating | |
---|---|---|---|
Capacity | kW | 12.00 | 14.00 |
Input Power | kW | 3,89 | 3,88 |
SEER - Energy Class - Cooling | W/W | A | - |
SCOP - Energy class - Heating | W/W | A | |
Operation Range | °C DB | -15~46 | -15~24 |
System data | |||
---|---|---|---|
Running Current | A | 5,8 | 5,8 |
Power Source | V/O/Hz | 400/3/50 | |
Moisture Removal | I/h | 4,5 | |
Piping Connections (Small / Large) | mm | 9,52/15,88 | |
Max Pipe Length | m | 75 | |
Max Height Difference | m | 30 | |
Refrigerant | R410A |
unit | indoor | Outdoor | |
---|---|---|---|
Airflow Rate (High) | m?/h | 2.100 | 6.900 |
Net Dimension H x W x D | mm | 240x1660x700 | 1290×900×330 |
Weight | kg (lbs) | 46 (101) | 107 (236) |
Noise (H/Q) | dB(A) | 49/45/39/34 | 54 |
Drain Pipe Diameter | mm | 22,0 | 25,6 |