Description
- Compact, space-saving design
- Energy-saving DC inverter compressor
- Improved fan design
- Optimised air distribution accompanied by practically silent operation
- Dust and pollen filter as well as ion filter
- Quick-start function
- Temperature reduction to +10 °C for heating when rooms are not in use
Model
ASHG 09 LLCA | Indoor Unit |
AOHG 09 LLCA | Outdoor Unit |
Description Functions
-
Human sensor detects the movement of people in the room and judges whether the energy saving operation.
-
Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating
-
The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.
-
The setting temperature automatically returns to the previously set temperature.
-
Keeping the rated heating capacity even when the outdoor ambient temperature is -7°C.
-
Operation at maximum air flow and compressor speed, and quickly makes the room comfortable.
-
The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.
-
Sound noise level of outdoor unit can be selected.
-
The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.
-
The up/down flaps automatically swing up and down.
-
The micro-computer automatically adjusts the airflow effectively to follow the changes of room temperature.
-
In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once power supply is restored.
-
The micro-computer gradually changes the room temperature automatically to afford a comfortable night's sleep
-
This digital timer allows selection of one of four options: ON, OFF, ON » OFF or OFF « ON.
-
Different ON-OFF times can be set for each day
-
Weekly + Setback timer can set temperature for two times spans and for each day of the week.
-
Indicates the filter cleaning period by lamp.
-
External error output
-
External ON/OFF input
-
The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultrafine-particle ceramic.
-
The Apple-catechin filter uses static electricity to clean fine particles and dust in the air.
-
Since the front panel is easy to remove, maintenance is also easy.
-
All DC models
-
i-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform.
-
V-PAM inverter control reduces the effects of magnetic flux and increases the maximum speed and efficiency of the compressor by vector control technology
Operation mode | Cooling | Heating | |
---|---|---|---|
Capacity | kW | 2.50 | 3.00 |
Input Power | kW | 0,745 | 0,865 |
SEER - Energy Class - Cooling | W/W | 6,10 Клас A++ | - |
Annual Energy Consumption | kWh/a | 143 | 932 |
Operation Range | °C DB | 18~43 | -15~24 |
SCOP - Energy class - Heating | W/W | 4.00 A+ |
System data | |||
---|---|---|---|
Running Current | A | 4,0 | 4,7 |
Power Source | V/O/Hz | 230/1/50 | |
Moisture Removal | I/h | 1,3 | |
Piping Connections (Small / Large) | mm | 6,35/9,52 | |
Max Pipe Length | m | 15(10) | |
Max Height Difference | m | 10 | |
Refrigerant | R410A |
unit | indoor | Outdoor | |
---|---|---|---|
Airflow Rate (High) | m?/h | 720 | 1.710 |
Net Dimension H x W x D | mm | 262×820×206 | 535×663×293 |
Weight | kg (lbs) | 7,5(17) | 24(53) |
Noise (H/Q) | dB(A) | 43/38/33/22 | 47 |
Drain Pipe Diameter | mm | 13,8/15,8 | 16,7 |