• 15.00 kW
  • 18.00 kW
  • Area : 110 M2
10490.00lv.
Price with VAT
Description
  • Neuer, hocheffizienter DC-Ventilator
  • Volumenstrom und externe Pressung einstellbar
  • "Low-Noise"-Modus am Außengerät optional einstellbar
  • Verschiedene Fernbedienungen und Optionen wählbar
Model
ARHG 60 LHTA Indoor Unit
AOHG 60 LATT Outdoor Unit
Description Functions
  • Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating
    Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating
  • The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.
    The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.
  • The setting temperature automatically returns to the previously set temperature.
    The setting temperature automatically returns to the previously set temperature.
  • The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.
    The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.
  • Sound noise level of outdoor unit can be selected.
    Sound noise level of outdoor unit can be selected.
  • The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.
    The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.
  • The micro-computer automatically adjusts the airflow effectively to follow the changes of room temperature.
    The micro-computer automatically adjusts the airflow effectively to follow the changes of room temperature.
  • In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once power supply is restored.
    In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once power supply is restored.
  • Fresh air can be taken in by a fan which can be connected using external control unit.
    Fresh air can be taken in by a fan which can be connected using external control unit.
  • Automatically stops operation when a fixed time has elapsed from the start of operation
    Automatically stops operation when a fixed time has elapsed from the start of operation
  • The micro-computer gradually changes the room temperature automatically to afford a comfortable night's sleep
    The micro-computer gradually changes the room temperature automatically to afford a comfortable night's sleep
  • This digital timer allows selection of one of four options: ON, OFF, ON » OFF or OFF « ON.
    This digital timer allows selection of one of four options: ON, OFF, ON » OFF or OFF « ON.
  • Weekly + Setback timer can set temperature for two times spans and for each day of the week.
    Weekly + Setback timer can set temperature for two times spans and for each day of the week.
  • Indicates the filter cleaning period by lamp.
    Indicates the filter cleaning period by lamp.
  • External error output
    External error output
  • External ON/OFF input
    External ON/OFF input
  • Blue fin
    Blue fin
  • All DC models
    All DC models
  • i-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform.
    i-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform.
  • V-PAM inverter control reduces the effects of magnetic flux and increases the maximum speed and efficiency of the compressor by vector control technology
    V-PAM inverter control reduces the effects of magnetic flux and increases the maximum speed and efficiency of the compressor by vector control technology
Operation modeCooling Heating 
Capacity kW 15.00 18.00
Input Power kW 4,70 5,15
Operation Range °C DB -15~46 -15~24
System data  
Running Current A 6,9 7,6
Power Source V/O/Hz 400/3/50
Moisture Removal I/h 23,4/25,4
Piping Connections (Small / Large) mm 2,0
Max Pipe Length m 75
Max Height Difference m 30
Refrigerant R410A
unit indoorOutdoor
Airflow Rate (High) m?/h 3.550 6.900
Net Dimension H x W x D mm 425x1250x490 1290x900x330
Weight kg (lbs) 54(119) 104(229)
Noise (H/Q) dB(A) 45/40/36 56
Drain Pipe Diameter mm 400/3/50
Related Posts
Price with VAT:
7750.00
  • Quiet as a whisper with high static compression
  • Compact design
  • Relatively lightweight
  • Large air volume flow
  • Remote control with temperature sensor for improved convenience
  • Also available with high static compression
  • Optional remote sensor
Price with VAT:
0.00
  • Quiet as a whisper with high static compression
  • Compact design
  • Relatively lightweight
  • Large air volume flow
  • Remote control with temperature sensor for improved convenience
  • Optional remote senso
Price with VAT:
5520.00