• 12.10 kW
  • 13.50 kW
  • Area : 110 M2
8150.00lv.
Price with VAT
Description
Model
ARXG45KHTAP Indoor Unit
AOHG45KRTA Outdoor Unit
Description Functions
  • Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating
    Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating
  • The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.
    The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.
  • The setting temperature automatically returns to the previously set temperature.
    The setting temperature automatically returns to the previously set temperature.
  • The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.
    The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.
  • The micro-computer automatically adjusts the airflow effectively to follow the changes of room temperature.
    The micro-computer automatically adjusts the airflow effectively to follow the changes of room temperature.
  • In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once power supply is restored.
    In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once power supply is restored.
  • Outside air can be introduced by attaching Locally purchased duct to fresh air knockout and optional part.
    Outside air can be introduced by attaching Locally purchased duct to fresh air knockout and optional part.
  • Automatically stops operation when a fixed time has elapsed from the start of operation
    Automatically stops operation when a fixed time has elapsed from the start of operation
  • Different ON-OFF times can be set for each day
    Different ON-OFF times can be set for each day
  • Indicates the filter cleaning period by lamp.
    Indicates the filter cleaning period by lamp.
  • External ON/OFF input
    External ON/OFF input
  • Automatically detects required airflow in each application case and adjust the volume.
    Automatically detects required airflow in each application case and adjust the volume.
  • Drain pump as standard
    Drain pump as standard
  • Blue fin
    Blue fin
  • All DC models
    All DC models
  • i-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform.
    i-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform.
  • V-PAM inverter control reduces the effects of magnetic flux and increases the maximum speed and efficiency of the compressor by vector control technology
    V-PAM inverter control reduces the effects of magnetic flux and increases the maximum speed and efficiency of the compressor by vector control technology
  • New eco-friendly refrigerant which has a lower global warming potential of one-third than R410A
    New eco-friendly refrigerant which has a lower global warming potential of one-third than R410A
Operation modeCooling Heating 
Capacity kW 12.10 13.50
Input Power kW 3.53 3.37
Operation Range °C DB -15~46 -15~24
External static pressure - (Extra high)/High/Low Pa 30 - 200
unit indoorOutdoor
Airflow Rate (High) m?/h 2550 4450
Net Dimension H x W x D mm 300×1400×700 998x940x320
Weight kg (lbs) 46 67
Noise (H/Q) dB(A) 39/29 57
System data  
Running Current A 14.0 14.0
Power Source V/O/Hz 400/3/50
Moisture Removal I/h 2.6
Piping Connections (Small / Large) mm 9.52 15.88
Max Pipe Length m 50
Max Height Difference m 30
Refrigerant R32