Description
Model
ARXG22KHTAP | Indoor Unit |
AOHG22KBTB | Outdoor Unit |
Description Functions
-
Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating
-
The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.
-
The setting temperature automatically returns to the previously set temperature.
-
The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.
-
The micro-computer automatically adjusts the airflow effectively to follow the changes of room temperature.
-
In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once power supply is restored.
-
Outside air can be introduced by attaching Locally purchased duct to fresh air knockout and optional part.
-
Automatically stops operation when a fixed time has elapsed from the start of operation
-
Different ON-OFF times can be set for each day
-
Indicates the filter cleaning period by lamp.
-
External ON/OFF input
-
Automatically detects required airflow in each application case and adjust the volume.
-
Drain pump as standard
-
Blue fin
-
All DC models
-
i-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform.
-
V-PAM inverter control reduces the effects of magnetic flux and increases the maximum speed and efficiency of the compressor by vector control technology
-
New eco-friendly refrigerant which has a lower global warming potential of one-third than R410A
Operation mode | Cooling | Heating | |
---|---|---|---|
Capacity | kW | 6.00 | 7.00 |
Input Power | kW | 1.71 | 1.81 |
SEER - Energy Class - Cooling | W/W | 6.50 A++ | |
SCOP - Energy class - Heating | W/W | 4.20 A+ | |
Operation Range | °C DB | -15~46 | -15~24 |
External static pressure - (Extra high)/High/Low | Pa | 30 - 200 |
unit | indoor | Outdoor | |
---|---|---|---|
Airflow Rate (High) | m?/h | 1050 | 2240 |
Net Dimension H x W x D | mm | 300×1000×700 | 632х799х290 |
Weight | kg (lbs) | 35 | 38 |
Noise (H/Q) | dB(A) | 28/20 | 51 |
System data | |||
---|---|---|---|
Running Current | A | 12.6 | 12.6 |
Power Source | V/O/Hz | 230/1/50 | |
Moisture Removal | I/h | 1.5 | |
Piping Connections (Small / Large) | mm | 6.35 | 12.70 |
Max Pipe Length | m | 30 | |
Max Height Difference | m | 25 | |
Refrigerant | R32 |