Description
- Ceiling or wall installation
- Static pressure from 30 to 200 Pa
- Fresh air intake
- Seasonal efficiency SCOP - 3.81 A, SEER - 5.81 A+
- Quiet operation thanks to V-shaped heat exchanger and air stabilizer
- Automatic airflow adjustment function, which regulates the volume depending on the room type
- Group operation
- Possibility to connect with BMS
- Timers for precise operational control
Model
ARHG36LHTBP | Indoor Unit |
AOHG36LBTA | Outdoor Unit |
Description Functions
-
Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating
-
The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.
-
The setting temperature automatically returns to the previously set temperature.
-
The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.
-
The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.
-
The micro-computer automatically adjusts the airflow effectively to follow the changes of room temperature.
-
In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once power supply is restored.
-
Outside air can be introduced by attaching Locally purchased duct to fresh air knockout and optional part.
-
Fresh air can be taken in by a fan which can be connected using external control unit.
-
Automatically stops operation when a fixed time has elapsed from the start of operation
-
The micro-computer gradually changes the room temperature automatically to afford a comfortable night's sleep
-
This digital timer allows selection of one of four options: ON, OFF, ON » OFF or OFF « ON.
-
Different ON-OFF times can be set for each day
-
Indicates the filter cleaning period by lamp.
-
External error output
-
External ON/OFF input
-
Automatically detects required airflow in each application case and adjust the volume.
-
Drain pump as standard
-
Blue fin
-
All DC models
-
i-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform.
Operation mode | Cooling | Heating | |
---|---|---|---|
Capacity | kW | 9.40 | 11.20 |
Input Power | kW | 2.83 | 3.07 |
SEER - Energy Class - Cooling | W/W | 5.81 A+ | |
SCOP - Energy class - Heating | W/W | 3.81 A | |
Annual Energy Consumption | kWh/a | 566 | 3194 |
Operation Range | °C DB | -15 ~ 46 | -15 ~ 24 |
unit | indoor | Outdoor | |
---|---|---|---|
Airflow Rate (High) | m?/h | 2050 | 3800 |
Net Dimension H x W x D | mm | 300x1400x700 | 830x900x330 |
Weight | kg (lbs) | 46 | 61 |
Noise (H/Q) | dB(A) | 36/26 | 55/54 |
Drain Pipe Diameter | mm | 25/32 |
System data | |||
---|---|---|---|
Power Source | V/O/Hz | 230/1/50 | |
Moisture Removal | I/h | 2.0 | |
Piping Connections (Small / Large) | mm | 9.52/15.88 | |
Max Pipe Length | m | 50 | |
Max Height Difference | m | 30 | |
Refrigerant | R410A |
Related Posts
- Ceiling or wall installation
- Static pressure from 30 to 200 Pa
- Fresh air intake
- Seasonal efficiency SCOP - 4,10 A+, SEER - 6.20 A++
- Quiet operation thanks to V-shaped heat exchanger and air stabilizer
- Automatic airflow adjustment function, which regulates the volume depending on the room type
- Group operation
- Possibility to connect with BMS
- Timers for precise operational control
Price with VAT:
2900.00