• A++7.05
  • 5.20 kW
  • 6.00 kW
  • Area : 30 M2
4150.00lv.
Price with VAT
Description
  • New circular flow series for big rooms
  • High seasonal efficiency SEER 7,05 А++, SCOP 4,40 А+
  • Unique circular flow design
  • Confortable environment – uniform temperature distribution through wide airflow
  • Quiet operation
  • Fresh air intake
  • Timers for precise operational control
  • Individual louvre control via touch-screen controller
  • Human sensor – efficient energy-saving control
  • Low ambient operation
Model
AUXG18LRLB Indoor Unit
AOHG18LBCA Outdoor Unit
Description Functions
  • Human sensor detects the movement of people in the room and judges whether the energy saving or stop operation.
    Human sensor detects the movement of people in the room and judges whether the energy saving or stop operation.
  • Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating
    Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating
  • The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.
    The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.
  • The setting temperature automatically returns to the previously set temperature.
    The setting temperature automatically returns to the previously set temperature.
  • The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.
    The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.
  • The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.
    The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.
  • The up/down flaps automatically swing up and down.
    The up/down flaps automatically swing up and down.
  • The micro-computer automatically adjusts the airflow effectively to follow the changes of room temperature.
    The micro-computer automatically adjusts the airflow effectively to follow the changes of room temperature.
  • In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once power supply is restored.
    In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once power supply is restored.
  • Outside air can be introduced by attaching Locally purchased duct to fresh air knockout and optional part.
    Outside air can be introduced by attaching Locally purchased duct to fresh air knockout and optional part.
  • Fresh air can be taken in by a fan which can be connected using external control unit.
    Fresh air can be taken in by a fan which can be connected using external control unit.
  • Systems are capable of attaching Locally purchased branch ducts distributing the airflow.
    Systems are capable of attaching Locally purchased branch ducts distributing the airflow.
  • Each louver of 4-way Cassette type can be controlled individually and provides comfortable airflow.
    Each louver of 4-way Cassette type can be controlled individually and provides comfortable airflow.
  • Automatically stops operation when a fixed time has elapsed from the start of operation
    Automatically stops operation when a fixed time has elapsed from the start of operation
  • The micro-computer gradually changes the room temperature automatically to afford a comfortable night's sleep
    The micro-computer gradually changes the room temperature automatically to afford a comfortable night's sleep
  • This digital timer allows selection of one of four options: ON, OFF, ON » OFF or OFF « ON.
    This digital timer allows selection of one of four options: ON, OFF, ON » OFF or OFF « ON.
  • Different ON-OFF times can be set for each day
    Different ON-OFF times can be set for each day
  • Indicates the filter cleaning period by lamp.
    Indicates the filter cleaning period by lamp.
  • External error output
    External error output
  • External ON/OFF input
    External ON/OFF input
  • All DC models
    All DC models
  • i-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform.
    i-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform.
Operation modeCooling Heating 
Capacity kW 5.20 6.00
Input Power kW 1.42 1.50
SEER - Energy Class - Cooling W/W 7.05 A++
SCOP - Energy class - Heating W/W 4.40 A+
Annual Energy Consumption kWh/a 258 1367
Operation Range °C DB -15 ~ 46 -15 ~ 24
unit indoorOutdoor
Airflow Rate (High) m?/h 1050 1900
Net Dimension H x W x D mm 246x840x840 620x790x290
Weight kg (lbs) 24 41
Noise (H/Q) dB(A) 33/28 51/50
Drain Pipe Diameter mm 25/32
Net Dimension H x W x D / Grille mm 53x950x950
System data  
Power Source V/O/Hz 230/1/50
Moisture Removal I/h 2.2
Piping Connections (Small / Large) mm 6.35/12.7
Max Pipe Length m 30
Max Height Difference m 20
Refrigerant R410A
Related Posts
Price with VAT:
6050.00
Price with VAT:
4650.00
  • New circular flow series for big rooms
  • High seasonal efficiency SEER 7,05 А++, SCOP 4,40 А+
  • Unique circular flow design
  • Confortable environment – uniform temperature distribution through wide airflow
  • Quiet operation
  • Fresh air intake
  • Timers for precise operational control
  • Individual louvre control via touch-screen controller
  • Human sensor – efficient energy-saving control
  • Low ambient operation
Price with VAT:
4150.00