Description
- Compact, space-saving design
- Latest generation of high-performance heat exchangers
- Dust and pollen filter as well as ionisation filter
- Indoor unit with new attractive design
- Easy installation thanks to lighter and smaller outdoor unit
Model
ASHG 18 LFCA | Indoor Unit |
AOHG 18 LFC | Outdoor Unit |
Description Functions
-
Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating
-
An additional louver that opens based on monitoring sensors to quickly enhance immediate comfort needs
-
The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.
-
The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.
-
Complex swing action of flaps enables automatically to swing both horizontal and vertical directions.
-
The micro-computer automatically adjusts the airflow effectively to follow the changes of room temperature.
-
In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once power supply is restored.
-
Automatically stops operation when a fixed time has elapsed from the start of operation
-
The micro-computer gradually changes the room temperature automatically to afford a comfortable night's sleep
-
This digital timer allows selection of one of four options: ON, OFF, ON » OFF or OFF « ON.
-
Weekly + Setback timer can set temperature for two times spans and for each day of the week.
-
Indicates the filter cleaning period by lamp.
-
External error output
-
External ON/OFF input
-
The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultrafine-particle ceramic.
-
The Apple-catechin filter uses static electricity to clean fine particles and dust in the air.
-
Since the front panel is easy to remove, maintenance is also easy.
-
Blue fin
-
All DC models
-
i-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform.
-
V-PAM inverter control reduces the effects of magnetic flux and increases the maximum speed and efficiency of the compressor by vector control technology
Operation mode | Cooling | Heating | |
---|---|---|---|
Capacity | kW | 5.20 | 6.30 |
Input Power | kW | 1,52 | 1,71 |
SEER - Energy Class - Cooling | W/W | 6,94 A++ | |
Annual Energy Consumption | kWh/a | 262 | 2130 |
Operation Range | °C DB | -10~46 | -15~24 |
SCOP - Energy class - Heating | W/W | 3,87 A |
System data | |||
---|---|---|---|
Running Current | A | 6,8 | 7,6 |
Power Source | V/O/Hz | 230/1/50 | |
Moisture Removal | I/h | 2,6 | |
Piping Connections (Small / Large) | mm | 6,35/12,8 | |
Max Pipe Length | m | 25 (15) | |
Max Height Difference | m | 20 | |
Refrigerant | R410A |
unit | indoor | Outdoor | |
---|---|---|---|
Airflow Rate (High) | m?/h | 900 | 2.150 |
Net Dimension H x W x D | mm | 320X998X238 | 620X790X298 |
Weight | kg (lbs) | 14 (30,8) | 41 (90) |
Noise (H/Q) | dB(A) | 43/37/33/26 | 50 |
Drain Pipe Diameter | mm | 16 | 29 |